UL20276

产品型号:UL20276

Style 20276








Multiconductor cable with extruded non-integral jacket



RATING
60 or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on construction B.
INSULATED CONDUCTOR
Labeled or complying with AWM Procedure. 40 AWG minimum.
ASSEMBLY
Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
COVERING
Optional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly.
SHIELD
Optional.
JACKET
Extruded PVC.

Construction A
Construction B
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any pointMinimum average thicknessMinimum thickness at any point
0.350 inch or less20 mils17 mils15 mils12 mils
0.351-0.700 inch30 mils24 mils30 mils24 mils
0.701-1.000 inch40 mils36 mils40 mils36 mils
1.101-1.500 inch54 mils48 mils54 mils48 mils
STANDARD
Appliance Wiring Material UL 758.
MARKING
General.
USE
Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only.