产品型号:UL2835
Style 2835 | |||
Multiple-Conductor Cable Using Extruded Non-Integral Jacket | |||
RATING | |||
60 deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use No. 1A and 2A. | |||
CONDUCTOR | |||
40 AWG minimum. | |||
INSULATED CONDUCTOR | |||
Material not specified for Use No. 1A or 1B. Labeled or complies with manufacturer's Procedure for Use No. 2A or 2B. | |||
ASSEMBLY | |||
Two or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. | |||
COVERING | |||
Optional. Extruded PVC, 5 mils minimum thickness at any point, over the assembly or groups of singles. | |||
SHIELD | |||
Optional. May be over one or more of the insulated conductors or applied over the assembly. | |||
JACKET | |||
Extruded PVC. If parallel construction is rippable, the measurements are made after ripping. | |||
Diameter of cable under jacket* | Minimum average thickness | Minimum thickness at any point | |
0.250 inch or less (1A & 2A only) | 15 mils | 13 mils | |
0.250 inch or less (1B & 2B only) | 30 mils | 27 mils | |
0.251-0.424 inch | 30 mils | 27 mils | |
0.425-0.700 inch | 60 mils | 48 mils | |
0.701-1.500 inch | 80 mils | 64 mils | |
1.501-2.500 inch | 110 mils | 88 mils | |
2.501 inch or larger | 140 mils | 112 mils | |
* = Major diameter if flat or oval construction. | |||
STANDARD | |||
Appliance Wiring Material UL 758. | |||
MARKING | |||
General. | |||
USE | |||
Use No. 1A:, Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 1B:, CABLES - using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 2A:, Internal wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.; Use No. 2B:, CABLES - using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits. |