UL线材文件

UL2785

产品型号:UL2785

Style 2785






Multiple-conductor cable using non-integral jacket.


RATING
60 deg C, 300 Vac, Horizontal flame.
INSULATION
Labeled or complying with Manufacturer's AWM Procedure
ASSEMBLY
Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. the conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
SHIELD
Optional.
COVERING
(Optional) - A 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly.
JACKET
Extruded PVC
major dia in inches


0.250 or less15 mils min average12 mils minimum at any point
0.25l-0.700 dia30 avg24 min
0.701-1.000 dia60 avg48 min
l.00l-l.500 dia80 avg64 min.
STANDARD
Appliance Wiring Material UL 758.
MARKING
General.
USE
Internal wiring of Electronic Equipment.