UL线材文件

UL2576

产品型号:UL2576

Style 2576






Multiple Conductor Cable with Extruded Non-integral Jacket


RATING
80 deg C, 150 Vac, Cable flame.
CONDUCTOR
36-9 AWG, solid or stranded.
INSULATED CONDUCTOR
Labeled or complying with Manufacturer's AWM Procedure.
ASSEMBLY
Two or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Cable may contain Labeled Flat Ribbon Style AWM which may be rolled or spiralled and formed around fillers or bunched singles. Fillers and/or tape wrap or extruded covering may be used.
COVERING
Optional, extruded PVC, 5 mils minimum thickness at any point, over one or more groups of conductors.
SHIELD
Optional. The shield may be over one or more of the insulated conductors or applied between the conductor assembly and the optional covering.
JACKET
Extruded PVC.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
1.000 inch or less30 mils24 mils
1.001-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
STANDARD
Appliance Wiring Material UL 758.
MARKING
General.
USE
External interconnection or internal wiring of electronic equipment.

相关产品

产品分类