产品型号:UL2448
Style 2448 |
Multiconductor Cable using Non-Integral Jacket |
RATING |
60 or 80 deg C, 30 Vac, Cable Flame. |
CONDUCTOR |
40 AWG minimum. |
INSULATED CONDUCTOR |
Labeled or complying with manufacturer's AWM procedure. |
ASSEMBLY |
Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
COVERING |
Optional, extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
SHIELD |
Optional. |
COVERING |
Optional, extruded PVC, 5 mils minimum thickness at any point. |
SHIELD |
Optional. |
JACKET |
Extruded PVC. |
Diameter of cable under jacket* |
0.425 inch or less |
0.426-0.700 inch |
0.701-1.000 inch |
1.001-1.500 inch |
1.501-2.500 inch |
2.501 inch and larger |
* - Major diameter if cable is flat or oval. |
STANDARD |
Appliance Wiring Material UL 758. |
MARKING |
General. |
USE |
Internal Wiring or External Interconnection in Class 2 Circuits of electronic equipment. |